loader image

ISO 1217:2009 – Displacement Compressors

ISO 1217:2009-Displacement compressors — Acceptance tests

What is ISO 1217:2009 – Displacement Compressors – Acceptance Tests?

ISO 1217:2009 specifies the acceptance tests for displacement compressors, which are machines that compress gases by reducing their volume. This standard applies to positive displacement compressors, which include reciprocating compressors, rotary screw compressors, and rotary vane compressors.

It outlines the procedures for conducting acceptance tests on displacement compressors to verify that they meet the specified performance requirements. The tests include measuring the compressor’s capacity, power consumption, and overall efficiency, as well as verifying that the compressor meets the manufacturer’s specifications for noise levels, vibration, and other operational parameters.

So, By conducting acceptance tests in accordance with ISO 1217:2009, compressor manufacturers and users can ensure that their equipment meets the required performance criteria, and that the compressor will operate reliably and efficiently over its expected service life.

Requirements of ISO 1217:2009

Test conditions: The acceptance tests should be performed under specified operating conditions. Including the type of gas being compressed, inlet and outlet pressure and temperature, and humidity.

Measurement accuracy: The measuring equipment used to conduct the acceptance tests should have sufficient accuracy and be calibrated according to recognized standards.

Capacity testing: The compressor’s capacity, which is the amount of gas that the compressor can deliver at a given pressure and temperature, should be measured in accordance with the specified test conditions.

Power consumption testing: The compressor’s power consumption, which is the amount of power required to operate the compressor, should be measured under the specified test conditions.

Efficiency testing: The compressor’s overall efficiency, which is the ratio of the compressor’s output to its input, should be calculated based on the results of the capacity and power consumption tests.

Noise and vibration testing: The acceptance tests should verify that the compressor meets the manufacturer’s specifications for noise and vibration levels.

Documentation: The results of the acceptance tests should be documented in a report, which should include a description of the test conditions, measurement procedures, and results.

By meeting these requirements, the acceptance tests can ensure that the displacement compressor meets the specified performance criteria. Also, operates reliably and efficiently over its expected service life.

Benefits of ISO 1217:2009

Verification of performance: The acceptance tests provide a standardized method to verify that the compressor meets the specified performance criteria. Including capacity, power consumption, and overall efficiency.

Consistency and comparability: The standardized testing procedures ensure that the results are consistent and comparable between different manufacturers and models of displacement compressors.

Improved reliability and efficiency: By ensuring that the compressor operates within the specified parameters, the acceptance tests can improve the reliability and efficiency of the compressor, which can result in reduced operating costs and increased uptime.

Compliance with regulations and standards: The acceptance tests can help manufacturers and users comply with local regulations and industry standards for compressed air systems.

Reduced risk of equipment failure: The acceptance tests can help identify potential issues with the compressor before it is put into service, reducing the risk of equipment failure and costly repairs.

Who needs ISO 1217:2009 – Displacement Compressors – Acceptance Tests?

Compressor manufacturers: Compressor manufacturers need ISO 1217:2009 acceptance tests to ensure that their products meet the specified performance criteria. Also, comply with industry standards and regulations.

Suppliers and distributors: Suppliers and distributors of displacement compressors need to verify that the compressors they purchase from manufacturers meet the specified performance criteria before they can sell them to end-users.

Users of compressed air systems: Users of compressed air systems, such as factories, workshops, and construction sites, need to ensure that the compressors they use are reliable and efficient and comply with relevant regulations and standards.

Regulatory bodies: Regulatory bodies, such as government agencies, industry associations, and independent testing organizations, may require compliance with the standard acceptance tests as part of their regulatory or certification process.

Compliance with ISO 1217:2009 acceptance tests, manufacturers, suppliers, and users of displacement compressors can ensure that their equipment is reliable, efficient, and compliant with relevant regulations and standards

Pacific Certifications is accredited by ABISClick here to apply for ISO 1217 or get in touch with us at +91-8595603096 or support@pacificcert.com

Read About: ISO 22005:2007-TRACEABILITY IN THE FEED AND FOOD CHAIN

Contact us to know more about ISO 1217:2009 – Displacement Compressors

Contact us Form POST Page

Related Certifications

Want to know more about ISO 1217:2009 – Displacement Compressors ?

Get in touch!

Email Address

support@pacificcert.com

Call Us

+918595603096

Free Cost Calculator

Get a rough Estimate for your Required Certification by entering your basic details.


Free Cost Calculator
  • Certification Required
  • Company Details
  • Contact Details
Please Select Service Type:

This will close in 0 seconds

Get in touch!

Contact us form

This will close in 0 seconds